Kokeile etsiä avainsanoilla, tuote- tai tilauskoodilla tai sarjanumerolla, esim. "CM442" tai "tekniset tiedot"
Aloita haku syöttämällä vähintään 2 merkkiä.
Prosonic FDU93 - Ultrasonic measurement

Ultrasonic measurement
Time-of-Flight
Prosonic FDU93

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 25m)

FDU93
Please Wait (spinning wheel)
Lataa hintaa
Hintoja ei tilap. saatavilla
Price on request
Suodata mittaus-/sovellustehtävä
Mittaus / sovellustehtävä

Konfiguroi ladataksesi tämän tuotteen CAD-kuvat

  • Mittausperiaate

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, PROFIBUS DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 43 psi)

  • Main wetted parts

    UP (unsaturated polyester)

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    Liquids: 25 m (85 ft),
    Solids: 15 m (50 ft)

  • Communication

    Transmitter:
    4...20 mA HART
    PROFIBUS DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

  • Options

    Second 4...20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    For tank farms scanner:
    FMU95

  • Mittausperiaate

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, PROFIBUS DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 43 psi)

  • Main wetted parts

    UP (unsaturated polyester)

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    Liquids: 25 m (85 ft),
    Solids: 15 m (50 ft)

  • Communication

    Transmitter:
    4 ... 20 mA HART
    PROFIBUS DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

  • Options

    Second 4...20mA output

  • Components

    Transmitter:
    FMU90