©Endress+Hauser
©Endress+Hauser
-
Successor
-
For level measurement in aggressive liquids or applications with hygiene requirements
-
Simple products
-
Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
-
Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
High-end products
-
Highly functional and convenient
Technical excellence
Simplicity
-
Specialized products
-
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections |
Technical excellence |
Simplicity |
Fundamental selection
Meet your basic measurement needs
|
Technical excellence
|
Simplicity
|
Lean selection
Handle your core processes easily
|
Technical excellence
|
Simplicity
|
Extended selection
Optimize your processes with innovative technologies
|
Technical excellence
|
Simplicity
|
Xpert selection
Master your most challenging applications
|
Technical excellence
|
Simplicity
|
-
Characteristic / Application
Characteristic / Application
-
Supply / Communication
2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)
-
-
-
Ambient temperature
-40 °C...+80 °C
(-40 °F...+176 °F)
-
Process temperature
-40° C...+200° C
(-40 °F...+392 °F)
-
Process pressure / max. overpressure limit
Vacuum...16 bar
(Vacuum...232 psi)
-
-
-
Process connection hygienic
Tri-Clamp ISO2852
DIN11851
-
-
Max. measurement distance
Max. measurement distance
-
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Certificates / Approvals
ATEX, FM, CSA, IECEx, TIIS, NEPSI
Overfill prevention WHG
SIL
EN 10204-3.1
Marine GL
3A, EHEDG
-
Most downloaded
-
Micropilot M FMR245
HART
Operating Instructions
English version - 06/2011
|
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
More
|
28/06/2011
|
|
|
|
30/07/2010
|
|
|
|
02/05/2008
|
|
|
|
28/02/2007
|
|
|
|
31/08/2006
|
|
|
|
Language:
|
English
|
Version:
|
28/06/2011
|
File size:
|
2.4 MB
|
File name:
|
BA00251FEN_1311.pdf
|
-
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245
Technical Information
English version - 10/2012
|
Continuous and non-contact level measurement.
Cost-effective 4 to 20 mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
More
|
01/10/2012
|
|
|
|
28/06/2011
|
|
|
|
31/01/2011
|
|
|
|
30/07/2010
|
|
|
|
17/12/2009
|
|
|
|
Language:
|
English
|
Version:
|
01/10/2012
|
File size:
|
4.4 MB
|
File name:
|
TI00345FEN_1512.pdf
|
129 documents
-
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245
Technical Information
Continuous and non-contact level measurement.
Cost-effective 4 to 20 mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
01/10/2012
|
|
|
|
28/06/2011
|
|
|
|
31/01/2011
|
|
|
|
30/07/2010
|
|
|
|
17/12/2009
|
|
|
|
Language:
|
English
|
Version:
|
01/10/2012
|
File size:
|
4.4 MB
|
File name:
|
TI00345FEN_1512.pdf
|
-
Micropilot M FMR230, 231
HART, PROFIBUS PA, FOUNDATION
Fieldbus
Description of Instrument Functions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
30/07/2010
|
|
|
|
03/08/2006
|
|
|
|
31/12/2005
|
|
|
|
22/12/2003
|
|
|
|
24/03/2003
|
|
|
|
Language:
|
English
|
Version:
|
30/07/2010
|
File size:
|
1.7 MB
|
File name:
|
BA221FEN_0310.pdf
|
-
Micropilot M FMR245
HART
Operating Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
28/06/2011
|
|
|
|
30/07/2010
|
|
|
|
02/05/2008
|
|
|
|
28/02/2007
|
|
|
|
31/08/2006
|
|
|
|
Language:
|
English
|
Version:
|
28/06/2011
|
File size:
|
2.4 MB
|
File name:
|
BA00251FEN_1311.pdf
|
-
Micropilot M FMR245
PROFIBUS PA
Operating Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
28/06/2011
|
|
|
|
30/07/2010
|
|
|
|
02/05/2008
|
|
|
|
28/02/2007
|
|
|
|
31/08/2006
|
|
|
|
Language:
|
English
|
Version:
|
28/06/2011
|
File size:
|
2.6 MB
|
File name:
|
BA00252FEN_1311.pdf
|
-
Micropilot M FMR240, 244, 245, 250
HART, PROFIBUS PA,
FOUNDATION Fieldbus
Description of Instrument Functions
Continuous and con-contact level measurement.
Cost-effective 4 to 20 mA 2-wíre technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
03/08/2006
|
|
|
|
31/01/2006
|
|
|
|
21/11/2005
|
|
|
|
01/08/2004
|
|
|
|
Language:
|
English
|
Version:
|
03/08/2006
|
File size:
|
1.8 MB
|
File name:
|
BA291FEN.pdf
|
-
Micropilot M FMR245
FOUNDATION Fieldbus
Operating
Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
28/06/2011
|
|
|
|
30/07/2010
|
|
|
|
02/05/2008
|
|
|
|
30/06/2007
|
|
|
|
31/05/2006
|
|
|
|
Language:
|
English
|
Version:
|
28/06/2011
|
File size:
|
3.3 MB
|
File name:
|
BA00253FEN_1311.pdf
|
-
Micropilot M FMR245
Brief Operating Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
31/12/2009
|
|
|
|
Language:
|
English
|
Version:
|
31/12/2009
|
File size:
|
987.6 KB
|
File name:
|
KA1012FEN_1209.pdf
|
-
Micropilot II/M - exchange of housing F12
Micropilot II/M - exchange of housing F12
|
EN
|
|
Select other language
|
15/04/2021
|
|
|
|
Language:
|
English
|
Version:
|
15/04/2021
|
File size:
|
194.9 KB
|
File name:
|
KA00556F00_A2.pdf
|
-
Screw set for Micropilot II/M, Levelflex M, Prosonic M
Screw set for Micropilot II/M, Levelflex M, Prosonic M
|
EN
|
|
Select other language
|
15/04/2021
|
|
|
|
Language:
|
English
|
Version:
|
15/04/2021
|
File size:
|
532.2 KB
|
File name:
|
KA00512F00_A2.pdf
|
-
Weather protection cover
Mounting Instruction
Weather protection cover for devices with F12/T12/F23 housing.
|
EN
|
|
Select other language
|
27/06/2007
|
|
|
|
31/05/2007
|
|
|
|
Language:
|
English
|
Version:
|
27/06/2007
|
File size:
|
235.5 KB
|
File name:
|
KA137Fa6_0607.pdf
|
Search spare parts by number in drawing
38 spare parts & accessories
38 spare parts
38 accessories
-
-
Cover F23 316L, sight glass, gasket
Drawing number
Order code
20
52018670
-
Drawing number
Order code
20
52018671
-
Cover F12/T12 Alu, window, gasket
Drawing number
Order code
20
52005936
-
Cover F12/T12 Alu, coated, gasket
Drawing number
Order code
20
517391-0011
-
Cover T3/T12 Alu, coated, gasket
Drawing number
Order code
25
518710-0020
-
Cover terminal compartment F12/F23
Drawing number
Order code
11
52006026
-
Cover terminal compartment F12/F23,FHX40
Drawing number
Order code
11
52019062
-
Drawing number
Order code
11
52005643
-
O-ring 113.9x3.63 EPDM, 5 pieces
-
Terminal module 4-pole, HART, 2-wire
Drawing number
Order code
35
52006197
-
Terminal module 4-pole, PA, FF
Drawing number
Order code
35
52012156
-
Terminal mod4-poleHART,ferrit,F12/F23
Drawing number
Order code
35
52014817
-
Terminal mod.4-p,PA/FF,ferrit,F12/F23
Drawing number
Order code
35
52014818
-
Terminal mod. Ex d, 4-pol., 2wr,HART,T12
Drawing number
Order code
35
52013302
-
Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12
Drawing number
Order code
35
52013303
-
Terminal mod. 4-pol.,EEx ia,HART,T12,OVP
Drawing number
Order code
35
52018949
-
Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP
Drawing number
Order code
35
52018950
-
HF module FMR24x, 26GHz, v.4.0
Drawing number
Order code
31
52006025
-
HF module FMR24x, 26GHz, v5.0
Drawing number
Order code
31
71026572
-
HF-module FMR24x, FMR250, 26GHz
Drawing number
Order code
31
52024953
-
Electronics FMR23x/FMR24x,Ex,HARTv4.0
Drawing number
Order code
30
71023757
-
Electronics FMR24x/250, Ex, HART,v5.0
Drawing number
Order code
30
71026754
-
Electronics FMR23x/FMR24x, Ex,PA,v4.0
Drawing number
Order code
30
71023758
-
Electronics FMR24x/250, Ex, PA, v5.0
Drawing number
Order code
30
71026819
-
Electronics FMR23x/FMR24x, Ex,FF,v4.0
Drawing number
Order code
30
71023759
-
Electronics FMR24x/250, Ex, FF, v5.0
Drawing number
Order code
30
71026820
-
Drawing number
Order code
40
52026443
-
Antenna FMR245, process connection
Drawing number
Order code
50
FMR245X-
-
-
Modification name plate, non Ex
-
Protective cover for housing T12/F12, SS
-
-
Mounting bracket FHX40 1" / 2" pipe
-
-
-
-
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .