Prosonic FDU90 - Ultrasonic measurement

Ultrasonic measurement
Time-of-Flight
Prosonic FDU91F

Hygienic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m)

FDU91F
Please Wait (spinning wheel)
Lataa hintaa
Hintoja ei tilap. saatavilla
Price on request
Suodata mittaus-/sovellustehtävä
Mittaus / sovellustehtävä

Konfiguroi ladataksesi tämän tuotteen CAD-kuvat

  • Mittausperiaate

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, PROFIBUS DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 105 °C
    (-40 °F ... 221 °F)

  • Process temperature

    -40 °C ... 105 °C
    (-40 °F ... 221 °F)
    CIP: 30 min: 135 °C
    (30 min: 275 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 4 bar abs
    (10 psi ... 58 psi)

  • Main wetted parts

    316L (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1", DN80 / 100, ASME 3" / 4"

  • Process connection hygienic

    Tri-Clamp ISO2852, DN80 3 1/2", DN100 4"

  • Blocking distance

    0.3 m (1 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    Transmitter:
    4 ... 20 mA HART
    PROFIBUS DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    Foam / high turbulence possible:
    FDU92
    For tank farms scanner:
    FMU95

  • Mittausperiaate

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, PROFIBUS DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 105 °C
    (-40 °F ... 221 °F)

  • Process temperature

    -40 °C ... 105 °C
    (-40 °F ... 221 °F)
    30 min: 135 °C / 275 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 4 bar abs
    (10 psi ... 58 psi)

  • Main wetted parts

    316L (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1", DN80 / 100, ASME 3" / 4"

  • Process connection hygienic

    Tri-Clamp ISO2852, DN80 (3 1/2"), DN100 (4")

  • Blocking distance

    0.3 m (1 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    Transmitter:
    4 ... 20 mA HART
    PROFIBUS DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

  • Design approvals

    EN 10204-3.1

  • Options

    Second 4...20 mA output

  • Components

    Transmitter:
    FMU90