Tärkeimmät tekniset tiedot
-
Max. measurement error
Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) -
Measuring range
0.5 to 10 m/s (1.6 to 33 ft/s)
-
Medium temperature range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional -
Max. process pressure
PN 40 / ASME Cl. 300 / JIS 20K
-
Wetted materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
Käyttöalue
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Device properties:
Full compliance according to NACE MR0175 and MR0103
Nominal diameter: DN 25 to 300 (1 to 12")
Medium temperature: –40 to 200 °C (–40 to 392 °F)
Device as compact or remote version
2-line backlit display with push buttons
HART, PROFIBUS PA, FOUNDATION Fieldbus
Edut
Safe design for process industries – international hazardous area approvals
No additional pressure loss – full-bore design
Process transparency – diagnostic capability
Easy installation and reduced installation costs – loop-powered transmitter
Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
Automatic recovery of data for servicing
Videot
Extended-valikoima
-
Laadukkaat tuotteet
- Erinomainen toiminnallisuus
Tekninen suorituskyky
Helppokäyttöisyys
-
Helppokäyttöiset tuotteet
- Helppoja valita, asentaa ja käyttää
Tekninen suorituskyky
Helppokäyttöisyys
-
Standardituotteet
- Luotettavat, lujatekoiset ja helppoja huoltaa
Tekninen suorituskyky
Helppokäyttöisyys
-
Laadukkaat tuotteet
- Erinomainen toiminnallisuus
Tekninen suorituskyky
Helppokäyttöisyys
-
Erikoistuotteet
- Suunniteltu vaativiin sovelluksiin
Tekninen suorituskyky
Helppokäyttöisyys
Tuotekohtainen
FLEX-valikoima | Tekninen suorituskyky | Helppokäyttöisyys |
---|---|---|
Fundamental-valikoima Täytä perusmittaustarpeesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Lean-valikoima Käsittele ydinprosessejasi helposti |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Extended-valikoima Optimoi prosessisi innovatiivisilla teknologioilla |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Xpert-valikoima Hallitse haastavimmatkin sovelluksesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
Tuotekohtainen |
-
-
Tekniset tiedot (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
Englanti - 11/2010
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN FI 05/11/201004/02/200901/06/2006Kieli:
Englanti
Versio:
05/11/2010
Tiedoston koko:
1.4 MB
Tiedoston nimi:
TI00073DEN_1310.pdf
-
-
-
Tekniset tiedot (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN FI 05/11/201004/02/200901/06/2006Kieli:
Englanti
Versio:
05/11/2010
Tiedoston koko:
1.4 MB
Tiedoston nimi:
TI00073DEN_1310.pdf
-
-
-
Käyttöohje (BA)
Proline Prosonic Flow 92F FOUNDATION Fieldbus Operating Instructions
Ultrasonic Flow Measuring System
EN FI 08/11/201001/02/2008Kieli:
Englanti
Versio:
08/11/2010
Tiedoston koko:
3.3 MB
Tiedoston nimi:
BA00128DEN_1310.pdf
-
-
-
Käyttöohje (BA)
Proline Prosonic Flow 92F Operating Instructions
Ultrasonic Flow Measuring System
EN FI 05/11/201001/06/2006Kieli:
Englanti
Versio:
05/11/2010
Tiedoston koko:
3.5 MB
Tiedoston nimi:
BA00121DEN_1310.pdf
-
-
-
Käyttöohje (BA)
Prosonic Flow 92F PROFIBUS PA Operating Instructions
Ultrasonic Flow Measuring System, 2-Wire loop powered inline
flowmeterEN FI 11/11/201001/06/2006Kieli:
Englanti
Versio:
11/11/2010
Tiedoston koko:
3.6 MB
Tiedoston nimi:
BA00122DEN_1310.pdf
-
-
-
Lyhyt ohje (KA)
Proline Prosonic Flow 92F Brief Operating Instructions
Ultrasonic flow measuring system
Two-wire inline flowmeterEN FI 01/09/2009Kieli:
Englanti
Versio:
01/09/2009
Tiedoston koko:
550.4 KB
Tiedoston nimi:
KA038DEN_0909.pdf
-
-
-
Asennusohjeet (EA)
EA Replacing cover and O-ring
Proline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN FI 15/10/202401/10/201828/06/2012Kieli:
Englanti
Versio:
15/10/2024
Tiedoston koko:
797.3 KB
Tiedoston nimi:
EA00098DA2_1624-00.pdf
-
-
-
Asennusohjeet (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN FI 01/03/201828/11/201325/04/2013Kieli:
Englanti
Versio:
01/03/2018
Tiedoston koko:
139.5 KB
Tiedoston nimi:
EA01051DA2_0318.pdf
-
-
-
Asennusohjeet (EA)
Repair kit cover remote version Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65EN FI 01/10/201813/11/201418/04/2014Kieli:
Englanti
Versio:
01/10/2018
Tiedoston koko:
216.9 KB
Tiedoston nimi:
EA01108DA2_0318.pdf
-
-
-
Asennusohjeet (EA)
EA Installing sensor parts
Prosonic Flow 92F, Prowirl 72, 73, 200
EN FI 16/10/202301/09/201714/01/201628/11/2013Kieli:
Englanti
Versio:
16/10/2023
Tiedoston koko:
2 MB
Tiedoston nimi:
EA01085DA2_0423-00.pdf
-
-
-
Asennusohjeet (EA)
Replacing the cable for the Sensor Installation Instructions
Prosonic Flow 92F
EN FI 03/06/201921/09/2016Kieli:
Englanti
Versio:
03/06/2019
Tiedoston koko:
415 KB
Tiedoston nimi:
EA01180DA2_0219.pdf
-