Tärkeimmät tekniset tiedot
-
Input
1-channel transmitter.
-
Output / communication
0/4-20mA, Hart, Profibus.
Käyttöalue
Liquisys COM253 is a standard transmitter for use with COS41 and COS61 oxygen sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
The Liquisys COM253 transmitter works with Oxymax COS41 and Oxymax COS61 dissolved oxygen sensors in environmental applications, such as:
O2 control in the aeration basin
O2 control and monitoring of drinking water
Surface water monitoring
Process water treatment and monitoring
O2 control in fish farming for optimum growth conditions
Liquisys COM253 features the following protocols and interfaces:
0/4...20 mA
HART
PROFIBUS DP
PROFIBUS PA
Edut
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Reliable oxygen control: Current input for flow rate monitoring with controller shut off or for feedforward control.
Easy to operate and service: Simple single-point calibration in air, air-saturated water or in the medium, direct access for manual contact control.
Reduced maintenance: Automatic cleaning function (with Chemoclean) triggered by alarm or limit switch.
Fit for every application: Numerous extensions, e.g. P(ID) controller, timer, etc., allow for flexible adaption to all processes.
Edeltäjä
-
Helppokäyttöiset tuotteet
- Helppoja valita, asentaa ja käyttää
Tekninen suorituskyky
Helppokäyttöisyys
-
Standardituotteet
- Luotettavat, lujatekoiset ja helppoja huoltaa
Tekninen suorituskyky
Helppokäyttöisyys
-
Laadukkaat tuotteet
- Erinomainen toiminnallisuus
Tekninen suorituskyky
Helppokäyttöisyys
-
Erikoistuotteet
- Suunniteltu vaativiin sovelluksiin
Tekninen suorituskyky
Helppokäyttöisyys
Tuotekohtainen
FLEX-valikoima | Tekninen suorituskyky | Helppokäyttöisyys |
---|---|---|
Fundamental-valikoima Täytä perusmittaustarpeesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Lean-valikoima Käsittele ydinprosessejasi helposti |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Extended-valikoima Optimoi prosessisi innovatiivisilla teknologioilla |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Xpert-valikoima Hallitse haastavimmatkin sovelluksesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
Tuotekohtainen |
-
-
Tekniset tiedot (TI)
Liquisys M COM223/253 Technical Information
Transmitter for oxygen sensors
EN FI Valitse toinen kieli 31/12/201424/10/201320/06/201111/09/200501/07/2005Kieli:
Englanti
Versio:
31/12/2014
Tiedoston koko:
822 KB
Tiedoston nimi:
TI00199CEN_1514.pdf
-
-
-
Käyttöohje (BA)
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
EN FI Valitse toinen kieli 01/12/201101/08/200901/09/200701/07/200601/10/2005Kieli:
Englanti
Versio:
01/12/2011
Tiedoston koko:
1.7 MB
Tiedoston nimi:
BA209CEN_1311.pdf
-
-
-
Käyttöohje (BA)
Model 840 / 842 Operating instructions
Transmitter for dissolved oxygen
Kieli:
Englanti
Versio:
01/07/2002
Tiedoston koko:
1.7 MB
Tiedoston nimi:
BA199e10.pdf
-
-
-
Käyttöohje (BA)
Liquisys M COM223/253 Operating Instructions
Transmitter
EN FI Valitse toinen kieli 01/09/201524/10/201320/06/201115/09/200501/07/2005Kieli:
Englanti
Versio:
01/09/2015
Tiedoston koko:
2.4 MB
Tiedoston nimi:
BA00199CEN_1515.pdf
-
-
-
Käyttöohje (BA)
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
EN FI Valitse toinen kieli 01/10/200501/07/2002Kieli:
Englanti
Versio:
01/10/2005
Tiedoston koko:
541.4 KB
Tiedoston nimi:
BA208CEN.pdf
-
-
-
Ex-turvallisuusohje (XA)
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous
areas as per EC Directive 94/9/EC (ATEX)EN FI Valitse toinen kieli 07/06/200527/09/200429/02/2004Kieli:
Englanti
Versio:
07/06/2005
Tiedoston koko:
2.5 MB
Tiedoston nimi:
XA194CA3.pdf
-
-
-
Erikoisasiakirjat (SD)
Instructions for service kits Liquisis M
Special documents
Instructions for service kits Liquisis M / CPM253 / CLM253 / COM253 /
CUM253EN FI Valitse toinen kieli 01/05/2000Kieli:
Englanti
Versio:
01/05/2000
Tiedoston koko:
198.2 KB
Tiedoston nimi:
SD084CA2.pdf
-
-
-
Erikoisasiakirjat (SD)
Installation of M 12 plug
Special Documentation Installation of M 12 plug
CPM253 / COM253 / CLM253 / CUM253EN FI Valitse toinen kieli 01/10/1999Kieli:
Englanti
Versio:
01/10/1999
Tiedoston koko:
85.5 KB
Tiedoston nimi:
SD052CA2.pdf
-
-
-
Erikoisasiakirjat (SD)
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Kieli:
Englanti
Versio:
24/09/2013
Tiedoston koko:
84.3 KB
Tiedoston nimi:
CXM2X3_Beiblatt for CSA.pdf
-
-
-
Valmistajan ilmoitus
Product family: Liquisys oxygen
Product root: COM253-
Declaration number: HE_02110_01.25
Manufacturer specification: RoHS
Additional information: China-RoHSEN FI Valitse toinen kieli 03/04/2025Kieli:
Englanti
Versio:
03/04/2025
Tiedoston koko:
365.8 KB
Tiedoston nimi:
HE_02110_01.25_COM253_China-RoHS_orange.pdf
-
-
-
EU-ilmoitus
Product family: Liquisys chlorine, Liquisys conductivity, Liquisys oxygen, Liquisys pH/ORP
Product root: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253-
Declaration number: EC_00575_02.23EN FI Valitse toinen kieli 17/07/2023Kieli:
Englanti
Versio:
17/07/2023
Tiedoston koko:
321 KB
Tiedoston nimi:
EC_00575_02.23_CxM2x3.pdf
-
-
-
Britannia vaatimustenmukaisuus arvioitu
Product family: Liquisys chlorine, Liquisys conductivity, Liquisys oxygen, Liquisys pH/ORP
Product root: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253-
Declaration number: UK_00563_01.23
Additional information: UK DoC for C*M2*3Kieli:
Englanti
Versio:
17/07/2023
Tiedoston koko:
308.4 KB
Tiedoston nimi:
UK_00563_01.23_CxM2x3.pdf
-
-
-
Tuotteen hiilijalanjälkitiedot
Product family: Liquisys oxygen
Product root: COM253-
Declaration number: ED_00197_01.24Kieli:
Englanti
Versio:
25/11/2024
Tiedoston koko:
138.5 KB
Tiedoston nimi:
ED_00197_01.24.pdf
-
-
-
Muuta
Product family: Liquiline, Liquiline M, Liquisys chlorine, Liquisys oxygen, Liquisys pH/ORP
Product root: CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM2
53-, CPM223-, CPM253-
Region: Eurasian Economic Union
Approval agency: EAC
Approval number: EAEC KZ 7500525.13.12.00621Kieli:
Venäjä
Versio:
06/02/2025
Tiedoston koko:
1.3 MB
Tiedoston nimi:
KZ 7500525.13.12.00621.pdf
-
-
-
Tavallinen sijainti tuoteturvallisuus
Product family: Liquisys chlorine, Liquisys conductivity, LIQUISYS M, LIQUISYS OXYGEN, Liquisys turbidity, SmarTec S
Product root: CCM223-, CCM253-, CLD134-, CLM223-, CLM223F-,
CLM253-, COM223-, COM223F-, COM253-, COM253F-, CPM223-, CPM253-, C
UM223-, CUM253-
Region: Canada, USA
Approval agency: CSAKieli:
Englanti
Versio:
12/04/2018
Tiedoston koko:
41.2 KB
Tiedoston nimi:
S4_COFC_000070173846_EN.pdf
-
-
-
Tarjousteksti
Liquisys COM253
Sauerstoff- und Temperatur Messumformer
Kieli:
Saksa
Versio:
20/12/2016
Tiedoston koko:
25 KB
Tiedoston nimi:
TTCOM253DE.doc
-
-
-
Yleisen aseman kuvaus (GSD)
General Station Description (GSD) - Liquisys Oxygen - PROFIBUS PA
Any, PROFIBUS System, Any
Tiedoston koko:
48.6 KB
Tiedoston nimi:
EH_PA_AN_Liquisys_0x1518_V02_00_PALIB.zip
Device Type:
0x1518
Firmware:
2.491
Version:
2.00.00
Date:
22/04/2014
-
-
-
Yleisen aseman kuvaus (GSD)
General Station Description (GSD) - Liquisys Oxygen - PROFIBUS DP
Any, PROFIBUS System, Any
Tiedoston koko:
48.1 KB
Tiedoston nimi:
EH_DP_AN_Liquisys_0x151E_V02_04_DPLIB.zip
Device Type:
0x151E
Firmware:
2.491
Version:
2.04.00
Date:
14/04/2014
-
-
-
Laitetyypin hallinta (DTM)
Device Type Manager (DTM) - Liquisys Oxygen - PROFIBUS PA
Endress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Tiedoston koko:
227.4 MB
Tiedoston nimi:
EH_Liquisys_M_COM_2x3_PA_V2_40__V2_41.zip
Device Type:
0x1518
Firmware:
2.491
Version:
1.5.153.348
Date:
15/05/2023
-
-
-
Laitetyypin hallinta (DTM)
Device Type Manager (DTM) - Liquisys Oxygen - HART
Endress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Tiedoston koko:
228 MB
Tiedoston nimi:
EH_Liquisys_M_DO_COM_2x3_V2_40.zip
Device Type:
0x0094
Device Revision:
1
Firmware:
2.47
Version:
1.4.188.39
Date:
12/05/2023
-