Tärkeimmät tekniset tiedot
-
Input
Chor / Chlordioxide and pH/ORP Sensor.
-
Output / communication
- Chlor/Chlordioxid, pH, Temperatur : 0/4-20mA- Profibus- Hart + 0/4-20mA
Käyttöalue
Liquisys CCM223 is a standard chlorine transmitter with integrated pH compensation for free chlorine. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
The Liquisys CCM223 transmitter works with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors in:
Water & Wastewater
- Disinfection process control and monitoring
- Desalination with membrane technology
- Swimming and whirl pools
- Gas scrubbersFood & Beverages
- Disinfection of process waterPower plants
- Cooling water disinfection
Liquisys CCM223 features the following protocols and interfaces:
0/4...20mA
HART
PROFIBUS DP
PROFIBUS PA
Edut
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Reliable chlorine and pH control: Current input for flow rate monitoring with controller shut off or for feedforward control.
Easy to operate and service: Intuitive user interface, simple calibration for chlorine and pH, direct access for manual contact control.
Reduced maintenance: Automatic cleaning function (with Chemoclean) triggered by alarm or limit switch.
Fit for every application: Numerous extensions, e.g. P(ID) controller, timer, etc., allow for flexible adaption to all processes.
Edeltäjä
-
Helppokäyttöiset tuotteet
- Helppoja valita, asentaa ja käyttää
Tekninen suorituskyky
Helppokäyttöisyys
-
Standardituotteet
- Luotettavat, lujatekoiset ja helppoja huoltaa
Tekninen suorituskyky
Helppokäyttöisyys
-
Laadukkaat tuotteet
- Erinomainen toiminnallisuus
Tekninen suorituskyky
Helppokäyttöisyys
-
Erikoistuotteet
- Suunniteltu vaativiin sovelluksiin
Tekninen suorituskyky
Helppokäyttöisyys
Tuotekohtainen
FLEX-valikoima | Tekninen suorituskyky | Helppokäyttöisyys |
---|---|---|
Fundamental-valikoima Täytä perusmittaustarpeesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Lean-valikoima Käsittele ydinprosessejasi helposti |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Extended-valikoima Optimoi prosessisi innovatiivisilla teknologioilla |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Xpert-valikoima Hallitse haastavimmatkin sovelluksesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
Tuotekohtainen |
-
-
Tekniset tiedot (TI)
Technical Information CCM 223/
Measurement of chlorine / chlorine dioxide/ total chlorine
Transmitter for chlorine sensorsEN FI 24/10/201320/06/201101/07/200601/09/2000Kieli:
Englanti
Versio:
24/10/2013
Tiedoston koko:
642.3 KB
Tiedoston nimi:
TI00214CEN_1413.pdf
-
-
-
Käyttöohje (BA)
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
EN FI 01/10/200501/07/2002Kieli:
Englanti
Versio:
01/10/2005
Tiedoston koko:
541.4 KB
Tiedoston nimi:
BA208CEN.pdf
-
-
-
Käyttöohje (BA)
Liquisys M COM223/253 Operating Instructions
Transmitter
EN FI 01/09/201524/10/201320/06/201115/09/200501/07/2005Kieli:
Englanti
Versio:
01/09/2015
Tiedoston koko:
2.4 MB
Tiedoston nimi:
BA00199CEN_1515.pdf
-
-
-
Käyttöohje (BA)
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
EN FI 01/12/201101/08/200901/09/200701/07/200601/10/2005Kieli:
Englanti
Versio:
01/12/2011
Tiedoston koko:
1.7 MB
Tiedoston nimi:
BA209CEN_1311.pdf
-
-
-
Käyttöohje (BA)
Käyttöohjeet Liquisys M CPM223/253
pH- ja ORP-lähetin
EN FI 01/09/201524/10/201320/06/201101/12/200501/03/2005Kieli:
Suomi
Versio:
24/10/2013
Tiedoston koko:
1.5 MB
Tiedoston nimi:
BA00194CFI_1413.pdf
-
-
-
Käyttöohje (BA)
Lyhennetty käyttöohje Liquisys M CLM 223/253
Lähetin johtokykymittauksiin
EN FI 01/09/201524/10/201320/06/201101/10/200815/09/2005Kieli:
Suomi
Versio:
01/05/1999
Tiedoston koko:
861.5 KB
Tiedoston nimi:
Ba193cfi.pdf
-
-
-
Käyttöohje (BA)
Liquisys M CCM223/253 Operating Instructions
Transmitter
EN FI 27/08/201524/10/201320/06/201101/07/200601/02/2003Kieli:
Englanti
Versio:
27/08/2015
Tiedoston koko:
2.7 MB
Tiedoston nimi:
BA00214CEN_1515.pdf
-
-
-
Ex-turvallisuusohje (XA)
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous
areas as per EC Directive 94/9/EC (ATEX)EN FI 07/06/200527/09/200429/02/2004Kieli:
Englanti
Versio:
07/06/2005
Tiedoston koko:
2.5 MB
Tiedoston nimi:
XA194CA3.pdf
-
-
-
Erikoisasiakirjat (SD)
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Kieli:
Englanti
Versio:
24/09/2013
Tiedoston koko:
84.3 KB
Tiedoston nimi:
CXM2X3_Beiblatt for CSA.pdf
-
-
-
EU-ilmoitus
Product family: Liquisys chlorine, Liquisys conductivity, Liquisys oxygen, Liquisys pH/ORP
Product root: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253-
Declaration number: EC_00575_02.23EN FI 17/07/2023Kieli:
Englanti
Versio:
17/07/2023
Tiedoston koko:
321 KB
Tiedoston nimi:
EC_00575_02.23_CxM2x3.pdf
-